Item Type: | Article |
---|---|
Title: | Survival and appropriate device interventions in recipients of cardioverter defibrillators implanted for the primary versus secondary prevention of sudden cardiac death |
Creators Name: | Stockburger, M., Krebs, A., Nitardy, A., Habedank, D., Celebi, O., Knaus, T. and Dietz, R. |
Abstract: | BACKGROUND: Implantable cardioverter-defibrillators (ICD) implanted after an episode of ventricular tachyarrhythmia (VTA) or in patients at high risk of VTA lower the long-term mortality. Comparisons of the clinical outcomes of the two indications are scarce. METHODS: The study enrolled 360 consecutive ICD recipients. The device was implanted for secondary prevention in 150 patients, whose mean age was 60 +/- 14 years, and mean left ventricular ejection fraction (LVEF) was 40 +/- 16%, and for primary prevention in 210 patients, whose mean age was 61 +/- 11 years, and mean LVEF was 31 +/- 13%. All-cause mortality and time to first appropriate ICD therapy were measured. RESULTS: The two study groups were similar with respect to age and prevalence of coronary artery disease. Mean LVEF was higher in the secondary prevention group (P = 0.001). Cox regression analysis revealed a significantly shorter time to first appropriate ICD therapy in the secondary prevention group (HR = 0.51, 95% CI = 0.30 - 0.87, P = 0.01). Over a mean follow-up of 37 +/- 19 months, the all-cause mortality in the overall population was 12.7%, and was similar in both subgroups (HR = 0.99, 95% CI = 0.55-1.77, P = 0.97). CONCLUSIONS: The long-term mortality in this unselected population of ICD recipients was low. Patients treated for secondary prevention received earlier appropriate ICD therapy than patients treated for primary prevention. Long-term mortality was similar in both groups. The higher VT incidence of VTA was effectively treated by the ICD and was not associated with a higher mortality. |
Keywords: | Implantable Cardioverter Defibrillator, Sudden Cardiac Death, Ventricular Tachyarrhythmia, Survival Analysis, Primary Prevention, Secondary Prevention |
Source: | Pacing and Clinical Electrophysiology |
ISSN: | 0147-8389 |
Publisher: | Blackwell Publishing |
Volume: | 32 Suppl 1 |
Page Range: | S16-S20 |
Date: | March 2009 |
Official Publication: | https://doi.org/10.1111/j.1540-8159.2008.02222.x |
PubMed: | View item in PubMed |
Repository Staff Only: item control page