Helmholtz Gemeinschaft

Search
Browse
Statistics
Feeds

Multicenter evaluation of label-free quantification in human plasma on a high dynamic range benchmark set

[thumbnail of Original Article]
Preview
PDF (Original Article) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
4MB
[thumbnail of Supplementary Information] Other (Supplementary Information)
24MB

Item Type:Article
Title:Multicenter evaluation of label-free quantification in human plasma on a high dynamic range benchmark set
Creators Name:Distler, Ute, Yoo, Han Byul, Kardell, Oliver, Hein, Dana, Sielaff, Malte, Scherer, Marian, Jozefowicz, Anna M., Leps, Christian, Gomez-Zepeda, David, von Toerne, Christine, Merl-Pham, Juliane, Barth, Teresa K., Tüshaus, Johanna, Giesbertz, Pieter, Müller, Torsten, Kliewer, Georg, Aljakouch, Karim, Helm, Barbara, Unger, Henry, Frey, Dario L., Helm, Dominic, Schwarzmüller, Luisa, Popp, Oliver, Qin, Di, Wudy, Susanne I., Sinn, Ludwig Roman, Mergner, Julia, Ludwig, Christina, Imhof, Axel, Kuster, Bernhard, Lichtenthaler, Stefan F., Krijgsveld, Jeroen, Klingmüller, Ursula, Mertins, Philipp, Coscia, Fabian, Ralser, Markus, Mülleder, Michael, Hauck, Stefanie M. and Tenzer, Stefan
Abstract:Human plasma is routinely collected during clinical care and constitutes a rich source of biomarkers for diagnostics and patient stratification. Liquid chromatography-mass spectrometry (LC-MS)-based proteomics is a key method for plasma biomarker discovery, but the high dynamic range of plasma proteins poses significant challenges for MS analysis and data processing. To benchmark the quantitative performance of neat plasma analysis, we introduce a multispecies sample set based on a human tryptic plasma digest containing varying low level spike-ins of yeast and E. coli tryptic proteome digests, termed PYE. By analysing the sample set on state-of-the-art LC-MS platforms across twelve different sites in data-dependent (DDA) and data-independent acquisition (DIA) modes, we provide a data resource comprising a total of 1116 individual LC-MS runs. Centralized data analysis shows that DIA methods outperform DDA-based approaches regarding identifications, data completeness, accuracy, and precision. DIA achieves excellent technical reproducibility, as demonstrated by coefficients of variation (CVs) between 3.3% and 9.8% at protein level. Comparative analysis of different setups clearly shows a high overlap in identified proteins and proves that accurate and precise quantitative measurements are feasible across multiple sites, even in a complex matrix such as plasma, using state-of-the-art instrumentation. The collected dataset, including the PYE sample set and strategy presented, serves as a valuable resource for optimizing the accuracy and reproducibility of LC-MS and bioinformatic workflows for clinical plasma proteome analysis.
Keywords:Benchmarking, Biomarkers, Blood Proteins, Escherichia Coli, Liquid Chromatography, Mass Spectrometry, Plasma, Proteome, Proteomics, Reproducibility of Results
Source:Nature Communications
ISSN:2041-1723
Publisher:Nature Publishing Group
Volume:16
Number:1
Page Range:8774
Date:2 October 2025
Official Publication:https://doi.org/10.1038/s41467-025-64501-z
PubMed:View item in PubMed
Related to:

Repository Staff Only: item control page

Downloads

Downloads per month over past year

Open Access
MDC Library