Helmholtz Gemeinschaft

Search
Browse
Statistics
Feeds

Comparison of modified Matyash method to conventional solvent systems for polar metabolite and lipid extractions

[img]
Preview
PDF (Original Article) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
2MB

Item Type:Article
Title:Comparison of modified Matyash method to conventional solvent systems for polar metabolite and lipid extractions
Creators Name:Sostare, J. and Di Guida, R. and Kirwan, J. and Chalal, K. and Palmer, E. and Dunn, W.B. and Viant, M.R.
Abstract:In the last decade, metabolomics has experienced significant advances in the throughput and robustness of analytical methodologies. Yet the preparation of biofluids and low-mass tissue samples remains a laborious and potentially inconsistent manual process, and a significant bottleneck for high-throughput metabolomics. To address this, we have compared three different sample extraction solvent systems in three diverse sample types with the purpose of selecting an optimum protocol for subsequent automation of sample preparation. We have investigated and re-optimised the solvent ratios in the recently introduced methyl tert-butyl ether (MTBE)/methanol/water solvent system (here termed modified Matyash; 2.6/2.0/2.4, v/v/v) and compared it to the original Matyash method (10/3/2.5, v/v/v) and the conventional chloroform/methanol/water (stepwise Bligh and Dyer, 2.0/2.0/1.8, v/v/v) using two biofluids (human serum and urine) and one tissue (whole Daphnia magna). This is the first report of the use of the Matyash method for extracting metabolites from the US National Institutes of Health (NIH) model organism D. magna. Extracted samples were analysed by non-targeted direct infusion mass spectrometry metabolomics or LC-MS metabolomics. Overall, the modified Matyash method yielded a higher number of peaks and putatively annotated metabolites compared to the original Matyash method (1-29% more peaks and 1-30% more metabolites) and the Bligh and Dyer method (4-20% more peaks and 1-41% more metabolites). Additionally the modified Matyash method was superior when considering metabolite intensities. The reproducibility of the modified Matyash method was higher than other methods (in 10 out of 12 datasets, compared to the original Matyash method; and in 8 out of 12 datasets, compared to the Bligh and Dyer method), based upon the observation of a lower mRSD of peak intensities. In conclusion, the modified Matyash method tended to provide a higher yield and reproducibility for most sample types in this study compared to two widely used methods.
Keywords:Metabolic Phenotyping, Lipidomics, Sample Extraction, Phase Separation, Chloroform, MTBE
Source:Analytica Chimica Acta
ISSN:0003-2670
Publisher:Elsevier
Volume:1037
Page Range:301-315
Date:11 December 2018
Additional Information:Erratum in: Anal Chim Acta 1091: 169.
Official Publication:https://doi.org/10.1016/j.aca.2018.03.019
PubMed:View item in PubMed

Repository Staff Only: item control page

Downloads

Downloads per month over past year

Open Access
MDC Library