Helmholtz Gemeinschaft

Search
Browse
Statistics
Feeds

Diagnostic efficacy of the magnetic resonance T1w/T2w ratio for the middle cerebellar peduncle in multiple system atrophy and spinocerebellar ataxia: a preliminary study

[img]
Preview
PDF (Original Article) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
1MB
[img] Other (Supporting Information)
23kB

Item Type:Article
Title:Diagnostic efficacy of the magnetic resonance T1w/T2w ratio for the middle cerebellar peduncle in multiple system atrophy and spinocerebellar ataxia: a preliminary study
Creators Name:Wang, J. and Sugiyama, A. and Yokota, H. and Hirano, S. and Cooper, G. and Mukai, H. and Ohira, K. and Koide, K. and Ito, S. and Finke, C. and Brandt, A.U. and Paul, F. and Kuwabara, S.
Abstract:BACKGROUND: The standardized T1-weighted/T2-weighted (sT1w/T2w) ratio for the middle cerebellar peduncle (MCP) has been reported to be sensitive for detecting degenerative changes in the cerebellar subtype of multiple system atrophy (MSA-C), even in the early stages. We aimed to investigate the diagnostic value of the MCP sT1w/T2w ratio for differentiating between MSA-C and spinocerebellar ataxia (SCA). METHODS: We included 32 MSA-C, 8 SCA type 3 (SCA3), 16 SCA type 6 (SCA6) patients, and 17 controls, and the MCP sT1w/T2w ratio was analyzed using a region-of-interest approach. The diagnostic performance of the MCP sT1w/T2w ratio in discriminating among MSA-C, SCA3, and SCA6 was assessed and compared with diagnosis based on visual interpretation of MCP hyperintensities and the "hot cross bun" (HCB) sign. RESULTS: MCP sT1w/T2w ratio values were markedly lower in patients with MSA-C than in those with SCA3, those with SCA6, and controls (p < 0.001). The MCP sT1w/T2w ratio showed high diagnostic accuracy for distinguishing MSA-C from SCA3 (area under curve = 0.934), SCA6 (area under curve = 0.965), and controls (area under curve = 0.980). The diagnostic accuracy of the MCP sT1w/T2w ratio for differentiating MSA-C from SCA3 or SCA6 (90.0% for MSA-C vs. SCA3, and 91.7% for MSA-C vs. SCA6) was comparable to or superior than that of visual interpretation of MCP hyperintensities (80.0-87.5% in MSA-C vs. SCA3 and 87.6-97.9% in MSA-C vs. SCA6) or the HCB sign (72.5-80.0% in MSA-C vs. SCA3 and 77.1-93.8% in MSA-C vs. SCA6). CONCLUSIONS: The MCP sT1w/T2w ratio might be a sensitive imaging-based marker for detecting MSA-C-related changes and differentiating MSA-C from SCA3 or SCA6.
Keywords:Hexachlorobenzene, Machado-Joseph Disease, Magnetic Resonance Imaging, Magnetic Resonance Spectroscopy, Middle Cerebellar Peduncle, Multiple System Atrophy, Spinocerebellar Ataxias
Source:PLoS ONE
ISSN:1932-6203
Publisher:Public Library of Science
Volume:17
Number:4
Page Range:e0267024
Date:15 April 2022
Official Publication:https://doi.org/10.1371/journal.pone.0267024
PubMed:View item in PubMed

Repository Staff Only: item control page

Downloads

Downloads per month over past year

Open Access
MDC Library