Helmholtz Gemeinschaft

Search
Browse
Statistics
Feeds

3D MRI of explanted sheep hearts with submillimeter isotropic spatial resolution: comparison between diffusion tensor and structure tensor imaging

[img]
Preview
PDF (Original Article) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
5MB
[img]
Preview
Image (TIFF) (Supplementary Information)
80MB

Item Type:Article
Title:3D MRI of explanted sheep hearts with submillimeter isotropic spatial resolution: comparison between diffusion tensor and structure tensor imaging
Creators Name:Magat, J. and Ozenne, V. and Cedilnik, N. and Naulin, J. and Haliot, K. and Sermesant, M. and Gilbert, S.H. and Trew, M. and Haissaguerre, M. and Quesson, B. and Bernus, O.
Abstract:OBJECTIVE: The aim of the study is to compare structure tensor imaging (STI) with diffusion tensor imaging (DTI) of the sheep heart (approximately the same size as the human heart). MATERIALS AND METHODS: MRI acquisition on three sheep ex vivo hearts was performed at 9.4 T/30 cm with a seven-element RF coil. 3D FLASH with an isotropic resolution of 150 µm and 3D spin-echo DTI at 600 µm were performed. Tensor analysis, angles extraction and segments divisions were performed on both volumes. RESULTS: A 3D FLASH allows for visualization of the detailed structure of the left and right ventricles. The helix angle determined using DTI and STI exhibited a smooth transmural change from the endocardium to the epicardium. Both the helix and transverse angles were similar between techniques. Sheetlet organization exhibited the same pattern in both acquisitions, but local angle differences were seen and identified in 17 segments representation. DISCUSSION: This study demonstrated the feasibility of high-resolution MRI for studying the myocyte and myolaminar architecture of sheep hearts. We presented the results of STI on three whole sheep ex vivo hearts and demonstrated a good correspondence between DTI and STI.
Keywords:Cardiac Microstructure, Fiber Organization, Sheetlet Organization, High-Resolution MRI, Helix Angle, Structure Tensor, Animals, Sheep
Source:Magnetic Resonance Materials in Physics Biology and Medicine
ISSN:0968-5243
Publisher:Springer
Volume:34
Number:5
Page Range:741-755
Date:October 2021
Official Publication:https://doi.org/10.1007/s10334-021-00913-4
PubMed:View item in PubMed

Repository Staff Only: item control page

Downloads

Downloads per month over past year

Open Access
MDC Library