Helmholtz Gemeinschaft

Search
Browse
Statistics
Feeds

Cerebral embolic lesions detected with diffusion-weighted magnetic resonance imaging following carotid artery stenting: a meta-analysis of 8 studies comparing filter cerebral protection and proximal balloon occlusion

Item Type:Article
Title:Cerebral embolic lesions detected with diffusion-weighted magnetic resonance imaging following carotid artery stenting: a meta-analysis of 8 studies comparing filter cerebral protection and proximal balloon occlusion
Creators Name:Stabile, E. and Sannino, A. and Schiattarella, G.G. and Gargiulo, G. and Toscano, E. and Brevetti, L. and Scudiero, F. and Giugliano, G. and Perrino, C. and Trimarco, B. and Esposito, G.
Abstract:OBJECTIVES: The aim of this meta-analysis was to evaluate and compare the efficacy of the 2 different neuroprotection systems in preventing embolization during carotid artery stenting (CAS), as detected by diffusion-weighted magnetic resonance imaging (DW-MRI). BACKGROUND: Data from randomized and nonrandomized studies comparing both types of embolic protection devices revealed contrasting evidence about their efficacy in neuroprotection, as assessed by the incidence of new ischemic lesions detected by DW-MRI. METHODS: Eight studies, enrolling 357 patients, were included in the meta-analysis. Our study analyzed the incidence of new ischemic lesions/patient, comparing filter cerebral protection and proximal balloon occlusion. RESULTS: Following CAS, the incidence of new ischemic lesions/patient detected by DW-MRI was significantly lower in the proximal balloon occlusion group (effect size [ES]: -0.43; 95% confidence interval [CI]: -0.84 to -0.02, I(2) = 70.08, Q = 23.40). Furthermore, following CAS, the incidence of lesions at the contralateral site was significantly lower in the proximal protection group (ES: -0.50; 95% CI: -0.72 to -0.27, I(2) = 0.00, Q = 3.80). CONCLUSIONS: Our meta-analysis supports the concept that the use of proximal balloon occlusion compared with filter cerebral protection is associated with a reduction of the amount of CAS-related brain embolization. The data should be confirmed by a randomized clinical trial.
Keywords:Carotid Artery Stenting, Cerebral Ischemic Lesions, Diffusion-Weighted Magnetic Resonance Imaging, Embolic Protection Device
Source:JACC: Cardiovascular Interventions
ISSN:1936-8798
Publisher:Elsevier
Volume:7
Number:10
Page Range:1177-1183
Date:October 2014
Official Publication:https://doi.org/10.1016/j.jcin.2014.05.019
PubMed:View item in PubMed

Repository Staff Only: item control page

Open Access
MDC Library