Helmholtz Gemeinschaft

Search
Browse
Statistics
Feeds

Comparability of compressed sensing-based gradient echo perfusion sequence SPARSE and conventional gradient echo sequence in assessment of myocardial ischemia

Item Type:Article
Title:Comparability of compressed sensing-based gradient echo perfusion sequence SPARSE and conventional gradient echo sequence in assessment of myocardial ischemia
Creators Name:Muehlberg, F., Stoetzner, A., Forman, C., Schmidt, M., Riazy, L., Dieringer, M., van der Geest, R., Schwenke, C. and Schulz-Menger, J.
Abstract:PURPOSE: Stress perfusion imaging plays a major role in non-invasive detection of coronary artery disease. We compared a compressed sensing-based and a conventional gradient echo perfusion sequence with regard to image quality and diagnostic performance. METHOD: Patients sent for coronary angiography due to pathologic stress perfusion CMR were recruited. All patients underwent two adenosine stress CMR using conventional TurboFLASH and prototype SPARSE sequence as well as quantitative coronary angiography with fractional flow reserve (FFR) within 6 weeks. Coronary angiography was considered gold standard with FFR < 0.75 or visual stenosis >90 % for identification of myocardial ischemia. Diagnostic performance of perfusion imaging was assessed in basal, mid-ventricular and apical slices by quantification of myocardial perfusion reserve (MPR) analysis utilizing the signal upslope method and a deconvolution technique using the fermi function model. RESULTS: 23 patients with mean age of 69.6 ± 8.9 years were enrolled. 46 % were female. Image quality was similar in conventional TurboFLASH sequence and SPARSE sequence (2.9 ± 0.5 vs 3.1 ± 0.7, p = 0,06). SPARSE sequence showed higher contrast-to-noise ratio (52.1 ± 27.4 vs 40.5 ± 17.6, p < 0.01) and signal-to-noise ratio (15.6 ± 6.2 vs 13.2 ± 4.2, p < 0.01) than TurboFLASH sequence. Dark-rim artifacts occurred less often with SPARSE (9 % of segments) than with TurboFLASH (23 %). In visual assessment of perfusion defects, SPARSE sequence detected less false-positive perfusion defects (n = 1) than TurboFLASH sequence (n = 3). Quantitative perfusion analysis on segment basis showed equal detection of perfusion defects for TurboFLASH and SPARSE with both upslope MPR analysis (TurboFLASH 0.88 ± 0.18; SPARSE 0.77 ± 0.26; p = 0.06) and fermi function model (TurboFLASH 0.85 ± 0.24; SPARSE 0.76 ± 0.30; p = 0.13). CONCLUSIONS: Compressed sensing perfusion imaging using SPARSE sequence allows reliable detection of myocardial ischemia.
Keywords:Perfusion, Compressed Sensing, CMR, Stress MRI, Coronary Artery Disease, Non-Invasive Stress Test
Source:European Journal of Radiology
ISSN:0720-048X
Publisher:Elsevier
Volume:131
Page Range:109213
Date:October 2020
Official Publication:https://doi.org/10.1016/j.ejrad.2020.109213
PubMed:View item in PubMed

Repository Staff Only: item control page

Open Access
MDC Library