Helmholtz Gemeinschaft

Search
Browse
Statistics
Feeds

B(1) inhomogeneity correction of RARE MRI with transceive surface radiofrequency probes

[img]
Preview
PDF (Original Article) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
2MB

Item Type:Article
Title:B(1) inhomogeneity correction of RARE MRI with transceive surface radiofrequency probes
Creators Name:Ramos Delgado, P. and Kuehne, A. and Periquito, J.S. and Millward, J.M. and Pohlmann, A. and Waiczies, S. and Niendorf, T.
Abstract:PURPOSE: The use of surface radiofrequency (RF) coils is common practice to boost sensitivity in (pre)clinical MRI. The number of transceive surface RF coils is rapidly growing due to the surge in cryogenically cooled RF technology and ultrahigh‐field MRI. Consequently, there is an increasing need for effective correction of the excitation field (B(1)(+)) inhomogeneity inherent in these coils. Retrospective B(1) correction permits quantitative MRI, but this usually requires a pulse sequence‐specific analytical signal intensity (SI) equation. Such an equation is not available for fast spin‐echo (Rapid Acquisition with Relaxation Enhancement, RARE) MRI. Here we present, test, and validate retrospective B(1) correction methods for RARE. METHODS: We implemented the commonly used sensitivity correction and developed an empirical model‐based method and a hybrid combination of both. Tests and validations were performed with a cryogenically cooled RF probe and a single‐loop RF coil. Accuracy of SI quantification and T(1) contrast were evaluated after correction. RESULTS: The three described correction methods achieved dramatic improvements in B(1) homogeneity and significantly improved SI quantification and T(1) contrast, with mean SI errors reduced from >40% to >10% following correction in all cases. Upon correction, images of phantoms and mouse heads demonstrated homogeneity comparable to that of images acquired with a volume resonator. This was quantified by SI profile, SI ratio (error < 10%), and percentage of integral uniformity (PIU > 80% in vivo and ex vivo compared to PIU > 87% with the reference RF coil). CONCLUSIONS: This work demonstrates the efficacy of three B(1) correction methods tailored for transceive surface RF probes and RARE MRI. The corrected images are suitable for quantification and show comparable results between the three methods, opening the way for T(1) measurements and X‐nuclei quantification using surface transceiver RF coils. This approach is applicable to other MR techniques for which no analytical SI exists.
Keywords:B(1) Correction, B(1) Inhomogeneity, MRI, RARE, Signal Intensity Equation, Transceive Surface RF Coils, Animals, Mice
Source:Magnetic Resonance in Medicine
ISSN:0740-3194
Publisher:Wiley
Volume:84
Number:5
Page Range:2684-2701
Date:November 2020
Official Publication:https://doi.org/10.1002/mrm.28307
PubMed:View item in PubMed

Repository Staff Only: item control page

Downloads

Downloads per month over past year

Open Access
MDC Library