PDF
- Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
1MB |
Item Type: | Article |
---|---|
Title: | An open-source software tool for the generation of relaxation time maps in magnetic resonance imaging |
Creators Name: | Messroghli, D.R., Rudolph, A., Abdel-Aty, H., Wassmuth, R., Kuhne, T., Dietz, R. and Schulz-Menger, J. |
Abstract: | BACKGROUND: In magnetic resonance (MR) imaging, T1, T2 and T2* relaxation times represent characteristic tissue properties that can be quantified with the help of specific imaging strategies. While there are basic software tools for specific pulse sequences, until now there is no universal software program available to automate pixel-wise mapping of relaxation times from various types of images or MR systems. Such a software program would allow researchers to test and compare new imaging strategies and thus would significantly facilitate research in the area of quantitative tissue characterization. RESULTS: After defining requirements for a universal MR mapping tool, a software program named MRmap was created using a high-level graphics language. Additional features include a manual registration tool for source images with motion artifacts and a tabular DICOM viewer to examine pulse sequence parameters. MRmap was successfully tested on three different computer platforms with image data from three different MR system manufacturers and five different sorts of pulse sequences: multi-image inversion recovery T1; Look-Locker/ TOMROP T1; modified Look-Locker inversion recovery (MOLLI) T1; single-echo T2/ T2*; and multi-echo T2/ T2*. Computing times varied between 2 and 113 seconds. Estimates of relaxation times compared favorably to those obtained from non-automated curve fitting. Completed maps were exported in DICOM format and could be read in standard software packages used for analysis of clinical and research MR data. CONCLUSIONS: MRmap is a flexible cross-platform research tool that enables accurate mapping of relaxation times from various pulse sequences. The software allows researchers to optimize quantitative MR strategies in a manufacturer-independent fashion. The program and its source code were made available as open-source software on the internet. |
Keywords: | Algorithms, Computer-Assisted Image Interpretation, Image Enhancement, Magnetic Resonance Imaging, Programming Languages, Reproducibility of Results, Sensitivity and Specificity, Software |
Source: | BMC Medical Imaging |
ISSN: | 1471-2342 |
Publisher: | BioMed Central |
Volume: | 10 |
Number: | 1 |
Page Range: | 16 |
Date: | 30 July 2010 |
Official Publication: | https://doi.org/10.1186/1471-2342-10-16 |
PubMed: | View item in PubMed |
Repository Staff Only: item control page