Helmholtz Gemeinschaft

Search
Browse
Statistics
Feeds

A multichannel time-domain scanning fluorescence mammograph: Performance assessment and first in vivo results

Item Type:Article
Title:A multichannel time-domain scanning fluorescence mammograph: Performance assessment and first in vivo results
Creators Name:Grosenick, D. and Hagen, A. and Steinkellner, O. and Poellinger, A. and Burock, S. and Schlag, P.M. and Rinneberg, H. and Macdonald, R.
Abstract:We present a scanning time-domain fluorescence mammograph capable to image the distribution of a fluorescent contrast agent within a female breast, slightly compressed between two parallel glass plates, with high sensitivity. Fluorescence of the contrast agent is excited using a near infrared picosecond diode laser module. Four additional picosecond diode lasers with emission wavelengths between 660 and 1066 nm allow to measure the intrinsic optical properties of the breast tissue. By synchronously moving a source fiber and seven detection fiber bundles across the breast, distributions of times of flight of photons are recorded simultaneously for selected source-detector combinations in transmission and reflection geometry either at the fluorescence wavelength or at the selected laser wavelengths. To evaluate the performance of the mammograph, we used breastlike rectangular phantoms comprising fluorescent and absorbing objects using the fluorescent dye Omocyanine as contrast agent excited at 735 nm. We compare two-dimensional imaging of the phantom based on transmission and reflection data. Furthermore, we developed an improved tomosynthesis algorithm which permits three-dimensional reconstruction of fluorescence and absorption properties of lesions with good spatial resolution. For illustration, we present fluorescence mammograms of one patient recorded 30 min after administration of the contrast agent indocyanine green showing the carcinoma at high contrast originating from fluorescence of the extravasated dye, excited at 780 nm.
Keywords:Algorithms, Breast Neoplasms, Feasibility Studies, Fluorescence Spectrometry, Imaging Phantoms, Limit of Detection, Mammography, Reproducibility of Results, Three-Dimensional Imaging, Time Factors
Source:Review of Scientific Instruments
ISSN:0034-6748
Publisher:American Institute of Physics
Volume:82
Number:2
Page Range:1024302
Date:February 2011
Official Publication:https://doi.org/10.1063/1.3543820
PubMed:View item in PubMed

Repository Staff Only: item control page

Open Access
MDC Library